Kingwin Lazer Platinum 550W Power Supply

Power
Viewing page 3 of 5 pages. Previous 1 2 3 4 5 Next

TESTING

For a fuller understanding of ATX power supplies, please read the reference article Power Supply Fundamentals. Those who seek source materials can find Intel's various PSU design guides at Form Factors.

SPCR's PSU Test Platform V4.1. is the basic setup for the testing. It is a close simulation of a moderate airflow mid-tower PC optimized for low noise. There is one major change: The primary testing is done with the PSU NOT inside the hotbox but atop it, out of the heat path. This is in recognition of several realities that prevail today:

  • In SPCR's test platform, the internal temperature varied proportionately with output load. The tested PSU was subject to this heat, and operating ambient temperature rose with increased load, reaching >40°C and often much higher at full power. This was a realistic simulation of a mid-tower PC case where the PSU is mounted conventionally at the top back portion of the case.
  • The vast majority of "serious" PC cases for the home builder place no longer position the PSU at the top back corner. They put the PSU at the bottom/back corner, mostly out of the path of heat from the other components in the case. This design concept took root with the Antec P180 going back over 5 years, and dominates the DIY case arena. This means the PSU generally has to dissipate only its own heat.

With the current test, we're reversing our approach: The PSU will be tested briefly in the hotbox only to check on what happens to noise, fan speed and temperatures when it is used in an outmoded case design

Acoustic measurements are performed in our own anechoic chamber with ambient level of 11 dBA or lower, with a PC-based spectrum analyzer comprised of SpectraPLUS software with ACO Pacific microphone and M-Audio digital audio interfaces.

REAL SYSTEM POWER NEEDS: While we test the PSU to full output in order to verify the manufacturer's claims, real desktop PCs simply do not require anywhere near this level of power. The most pertinent range of DC output power is between about 40W and 300W, because it is the power range where most systems will be working most of the time. It is true that very elaborate systems with the most power hungry dual video cards today might draw as much as another 150~300W, but the total should remain under 600W.

TEST RESULTS

The ambient temperature was 21~22°, and the ambient noise level was ~10.5 dBA.

Test Results: Kingwin LZP-550
DC Output (W)
AC Input
(W)
Lost as Heat
(W)
Efficiency %
Power Factor
Exhaust
SPL* (dBA@1m)
22.5
29
6.5
77.5
0.88
22°C
N/A
41.6
50
8.4
83.2
0.94
23°C
N/A
64.5
72
7.5
89.7
0.98
23°C
N/A
91.2
99
7.8
92.1
0.99
24°C
N/A
149.4
160
10.6
93.3
0.99
27°C
N/A
198.1
211
12.9
93.9
0.99
28°C
N/A
248.6
265
16.4
93.8
0.99
30°C
N/A
300.5
322
21.5
93.3
1.00
32°C
N/A
400.4
431
30.6
92.9
1.00
34°C
N/A
501.9
550
48.1
91.3
1.00
38°C
N/A
549.7
613
63.3
89.7
1.00
40/53°C
16
Crossload Test
(1A on 5V and 3.3V lines; the rest on 12V line)
485.6
519
23.4
93.6%
1.00
38°C
N/A
+12V Ripple (peak-to-peak): <13mV @ <250W ~ 34mV @ 550W
+5V Ripple (peak-to-peak): <10mV @ <200W ~ 30mV @ 550W
+3.3V Ripple (peak-to-peak): 10mV @ <200W ~ 24mV @ 550W
AC Power in Standby: 0.5W
AC Power with No Load, PSU power On: 6.8W / 0.56 PF
* See text discussion about noise.


1. EFFICIENCY This is a measure of AC-to-DC conversion efficiency. The ATX12V Power Supply Design Guide recommends 80% efficiency or better at all output power loads. 80% efficiency means that to deliver 80W DC output, a PSU draws 100W AC input, and 20W is lost as heat within the PSU. Higher efficiency is preferred for reduced energy consumption and cooler operation. It allows reduced cooling airflow, which translates to lower noise. The 80 Plus Platinum standard requires 90% efficiency at 20% load, 92% efficiency at 50% of rated load, and 89% at full rated load.

At the super low 20W load, efficiency was excellent at over 77%. Efficiency rose quickly as the load was increased. 90% efficiency was reached around the 65W mark, broke 93% by 150W, and stayed above 93% to 400W load. With higher load, efficiency dropped a bit. At full power, the efficiency dopped down to 89.7%, still above the mark demanded by Platinum.

This is the most energy efficient PSU we've tested yet, by a clearly measurable margin. It is a definite step above the Gold tested models, although admittedly, the difference in watts is quite small at typical PC idle levels (just a few watts) and does not become really significant until around a couple hundred watts load is reached. An example: The Gold 80 Plus rated Enermax Modu87+ 500W drew 76W AC to output 65W DC , compared to 72W for the Kingwin Platinum — a modest 4W difference. But at 200W output, the Gold rated Enermax drew 222W vs 211W for the Kingwin — a more significant 11W difference.

2. VOLTAGE REGULATION refers to how stable the output voltages are under various load conditions. The ATX12V Power Supply Design Guide calls for the +12, +5V and +3.3V lines to be maintained within ±5%.

At all load levels, the critical 12V line was within +0.36V (3%) of 12V. It started high, at 12.36V and dropped with increased load to 12.16V (+1.3%) at full load. The 5V line started a touch high, too, at 5.16V, and went down to 5.06V at full load (+3.2% to +1.2%). 3.3V ranged from 3.38V to 3.29V (+2.4% to -1.2%). These are excellent results, not the best we've seen but better than voltage regulation needs to be for any PC.

3. AC RIPPLE refers to unwanted "noise" artifacts in the DC output of a switching power supply. It's usually very high in frequency (in the order of 100s of kHz). The peak-to-peak value is measured. The ATX12V Guide allows up to 120mV (peak-to-peak) of AC ripple on the +12V line and 50mV on the +5V and +3.3V lines. Ripple on all the lines was excellent at all power levels, generally staying under 15mV through the lower half of the power range. Even at maximum power, the 12V ripple stayed at just 34mV. It's close to the best we have measured.

4. POWER FACTOR is ideal when it measures 1.0. In the most practical sense, PF is a measure of how "difficult" it is for the electric utility to deliver the AC power into your power supply. High PF reduces the AC current draw, which reduces stress on the electric wiring in your home (and elsewhere up the line). It also means you can do with a smaller, cheaper UPS backup; they are priced according to their VA (volt-ampere) rating. Power factor was very good for this model, running at or close to 1.0 through most of the loads and no lower than 0.88 even at just 20W load.

5. LOW LOAD TESTING revealed no problems starting at very low loads. Our sample had no issue starting up with no load, either, and the power draw was low. The 0.5W power draw in standby (power switch on but computer off) is excellent.

6. LOW & 240 VAC PERFORMANCE

The power supply was set to 300W load at various AC input voltages. Most full-range input power supplies achieve higher efficiency with higher AC input voltage. SPCR's lab is equipped with a 240VAC line, which was used to check power supply efficiency for the benefit of those who live in higher mains voltage regions. We also used a hefty variac to check the stability of the PSU under brownout conditions where the AC line voltage drops from the 120V norm.

Various VAC Inputs: Kingwin LZP-550
VAC
AC Power
DC Output
Efficiency
244V
314W
300W
95.4%
120V
322W
300W
93.3%
100V
327W
300W
91.7%

Efficiency improved to over 95% at the higher voltage. This is higher than the minimum 94% required by the 80 Plus Platinum standard for 230VAC operation. The sample passed the 100VAC minimum input at 300W load without any issues. Neither voltage regulation nor ripple changed appreciably during these tests.