Deepcool Gamer Storm Maelstrom 240 AIO Liquid Cooler

Cooling
Viewing page 4 of 7 pages. Previous 1 2 3 4 5 6 7 Next

TESTING

Before thermal testing, we took some basic physical measurements of the product(s) for comparison.

Large Heatsink Comparison:
Average Fin Thickness & Spacing
Heatsink
Fin Thickness
Fin Spacing
SilverStone Heligon HE02
0.52 mm
3.30 mm
Thermalright HR-01 Plus
0.45 mm
3.15 mm
Thermalright HR-02 Macho
0.34 mm
3.12 mm
Thermalright HR-22
0.53 mm
2.74 mm
Scythe Ninja 3
0.39 mm
2.64 mm
Noctua NH-U12P
0.44 mm
2.63 mm
Noctua NH-C12P
0.47 mm
2.54 mm
Cryorig H5 Universal
0.40 mm
2.47 mm
LEPA LV12
0.51 mm
2.38 mm
Noctua NH-D14
0.43 mm
2.33 mm
Thermalright Archon SB-E
0.49 mm
2.33 mm
Phanteks PH-TC12DX
0.39 mm
2.30 mm
GELID Tranquillo Rev.2
0.40 mm
2.30 mm
GELID GX-7 Rev.2
0.31 mm
2.25 mm
Be Quiet! Dark Rock Pro 3
0.40 mm
2.24 mm
Be Quiet! Dark Rock 2
0.38 mm
2.22 mm
Phanteks PH-TC14PE
0.40 mm
2.21 mm
Prolimatech Armageddon
0.51 mm
2.08 mm
Cryorig R1 Ultimate/Universal
0.42 mm
1.78 / 2.37 mm
Zalman CNPS10X Quiet
0.40 mm
2.00 mm
Prolimatech Megahalems
0.50 mm
2.00 mm
Scythe Ashura
0.43 mm
1.97 mm
NZXT Havik 140
0.41 mm
1.91 mm
Scythe Mugen-2
0.31 mm
1.89 mm
SilverStone Tundra TD03 (radiator)
0.43 mm
1.86 mm
SilverStone Argon AR01
0.30 mm
1.85 mm
Thermalright Venomous X
0.53 mm
1.84 mm
Scythe Mugen 4
0.30 mm
1.82 mm
Noctua NH-C14
0.38 mm
1.79 mm
Enermax ETS-T40
0.40 mm
1.79 mm
Noctua NH-D15
0.46 mm
1.79 mm
Scythe Yasya
0.32 mm
1.78 mm
Enermax Liqtech 120X (radiator)
0.46 mm
1.76 mm
Be Quiet! Shadow Rock Slim
0.42 mm
1.73 mm
SilverStone Argon AR03
0.42 mm
1.72 mm
Noctua NH-U14S
0.42 mm
1.72 mm
Cogage TRUE Spirit 1366
0.40 mm
1.70 mm
Scythe Kotetsu
0.35 mm
1.66 mm
Scythe Grand Kama Cross
0.38 mm
1.66 mm
Zalman CNPS9900 MAX
0.16 mm
1.59 mm
Thermalright Silver Arrow
0.32 mm
1.57 mm
Cooler Master Hyper 212 Plus
0.43 mm
1.54 mm
Thermalright Ultra-120 eXtreme Rev.C
0.56 mm
1.52 mm
Swiftech H240-X (radiator)
0.13 mm
1.80 mm
Deepcool Gamer Storm Maelstrom 240 (radiator)
0.26 mm
1.14 mm
NZXT Kraken X31/X41 (radiator)
0.15 mm
1.07 mm
NZXT Kraken X61 (radiator)
0.13 mm
1.02 mm

Larger heatsinks are tested on our LGA1366 heatsink testing platform, while smaller coolers tackle our LGA1155 heatsink testing platform. A summary of the test system and procedure follows.

Key Components in LGA1366 Heatsink Test Platform:

Key Components in LGA1155 Heatsink Test Platform:

The systems are silent under the test conditions, except for the CPU cooling fan(s).

Normally, our reference fans are used whenever possible, the measured details of which are shown below.

Reference Noctua 140mm fan
Anechoic chamber measurements
Voltage
Speed
12V
1250 RPM
28~29 dBA
9V
990 RPM
21 dBA
8V
880 RPM
18 dBA
7V
770 RPM
15~16 dBA
6V
660 RPM
13 dBA

Reference Nexus 120 mm fan
Anechoic chamber measurements
Voltage
Speed
12V
1080 RPM
16 dBA
9V
880 RPM
13 dBA
7V
720 RPM
12 dBA

Reference Nexus 92 mm fan
Anechoic chamber measurements
Voltage
Speed
12V
1470 RPM
17 dBA
9V
1280 RPM
14 dBA
7V
1010 RPM
12 dBA

Measurement and Analysis Tools

  • Extech 380803 AC power analyzer / data logger for measuring AC system power.
  • Custom-built, four-channel variable DC power supply, used to regulate the fan speed during the test.
  • PC-based spectrum analyzer: SpectraPlus with ACO Pacific mic and M-Audio digital audio interfaces.
  • Anechoic chamber with ambient level of 11 dBA or lower
  • Various other tools for testing fans, as documented in our standard fan testing methodology.
  • SpeedFan, used to monitor the on-chip thermal sensors. The sensors are not calibrated, so results are not universally applicable. The hottest core reading is used.
  • Prime95, used to stress the CPU heavily, generating more heat than most real applications. All instances are used to ensure full stress.
  • CPU-Z, used to monitor the CPU speed to determine when overheating occurs.
  • Thermometers to measure the air temperature around the test platform and near the intake of the heatsink fan.

Noise measurements are made with the fans powered from a separate, fanless system. Load testing was accomplished using Prime95 to stress the processor, and the graph function in SpeedFan was used to ensure that the load temperature is stable for at least ten minutes. The temperature recorded is the highest single core reading. The stock fans were tested at various voltages to represent a good cross-section of airflow and noise performance.

The ambient conditions during testing were 10~11 dBA and 21~23°C.



Previous 1 2 3 4 5 6 7 Next

Cooling - Article Index
Help support this site, buy from one of our affiliate retailers!
Search: